Yale Image Finder

Search the actual image content of 481,751 (and growing!) Open Access images and figures from PubMed Central.


Search: Image Text (High Recall) Image Text (High Precision) Caption Abstract Title Full Text


Figure 6: Graphic representation of the standard and in house microorganism reduction against different sanitizers.

Image Text (High Precision): 11568 15442 25922 3178 5031 9372 ATCC INCQS Sodium aeruginosa alcaligenes diminuta fluorescens log picketti subtilis time

Other Images from "Chemical resistance of the gram-negative bacteria to different sanitizers in a water purification system":


Figure 1 Flow sheet of a typical purification sys...

Figure 5 Graphic representation of the standard a...

Figure 7 Graphic representation of the standard a...

Figure 4 Graphic representation of the standard a...

Figure 3 Graphic representation of the standard a...

Figure 6 Graphic representation of the standard a...

Figure 2 Graphic representation of the standard a...

[Full Text] [PDF]

Abstract

BackgroundPurified water for pharmaceutical purposes must be free of microbial contamination and pyrogens. Even with the additional sanitary and disinfecting treatments applied to the system (sequential operational stages), Pseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were isolated and identified from a thirteen-stage purification system. To evaluate the efficacy of the chemical agents used in the disinfecting process along with those used to adjust chemical characteristics of the system, over the identified bacteria, the kinetic parameter of killing time (D-value) necessary to inactivate 90% of the initial bioburden (decimal reduction time) was experimentally determined.MethodsPseudomonas aeruginosa, Pseudomonas fluorescens, Pseudomonas alcaligenes, Pseudomonas picketti, Flavobacterium aureum, Acinetobacter lowffi and Pseudomonas diminuta were called in house (wild) bacteria. Pseudomonas diminuta ATCC 11568, Pseudomonas alcaligenes INCQS , Pseudomonas aeruginosa ATCC 15442, Pseudomonas fluorescens ATCC 3178, Pseudomonas picketti ATCC 5031, Bacillus subtilis ATCC 937 and Escherichia coli ATCC 25922 were used as 'standard' bacteria to evaluate resistance at 25°C against either 0.5% citric acid, 0.5% hydrochloric acid, 70% ethanol, 0.5% sodium bisulfite, 0.4% sodium hydroxide, 0.5% sodium hypochlorite, or a mixture of 2.2% hydrogen peroxide (H2O2) and 0.45% peracetic acid.ResultsThe efficacy of the sanitizers varied with concentration and contact time to reduce decimal logarithmic (log10) population (n cycles). To kill 90% of the initial population (or one log10 cycle), the necessary time (D-value) was for P. aeruginosa into: (i) 0.5% citric acid, D = 3.8 min; (ii) 0.5% hydrochloric acid, D = 6.9 min; (iii) 70% ethanol, D = 9.7 min; (iv) 0.5% sodium bisulfite, D = 5.3 min; (v) 0.4% sodium hydroxide, D = 14.2 min; (vi) 0.5% sodium hypochlorite, D = 7.9 min; (vii) mixture of hydrogen peroxide (2.2%) plus peracetic acid (0.45%), D = 5.5 min.ConclusionThe contact time of 180 min of the system with the mixture of H2O2+ peracetic acid, a total theoretical reduction of 6 log10 cycles was attained in the water purified storage tank and distribution loop. The contact time between the water purification system (WPS) and the sanitary agents should be reviewed to reach sufficient bioburden reduction (over 6 log10).


Search: Image Text (High Recall) Image Text (High Precision) Caption Abstract Title Full Text

All images and content copyright their respective owners. All else copyright ©2007-2008, Krauthammer Lab, Yale University.

Sign up for Yale Image Finder announcements:

Email: